Skip to product information
1 of 4

Xcem

Xcem XVT Tissue Level Dental Implants

Xcem XVT Tissue Level Dental Implants

Regular price Rs. 4,999.00
Regular price Sale price Rs. 4,999.00
Sale Sold out

Features

  • Titanium 6AL 4V construction for durability and biocompatibility.
  • SLA surface with increased surface area for optimal tissue-level contouring.
  • 2.5 Hex indentation and 11-degree Morse Taper for a secure connection.
  • Dual thread design with 0.8mm pitch for reduced surgical time.
  • Twist Type cutting edge for self-tapping ability and minimized bone resistance.
  • Micro thread technology with 0.2mm depth for enhanced initial fixation.
  • Tapered apex with dimensions tailored for stability in various implant sizes.
  • Titanium 6AL 4V construction for durability and biocompatibility.
  • SLA surface with increased surface area for optimal tissue-level contouring.
  • 2.5 Hex indentation and 11-degree Morse Taper for a secure connection.
  • Dual thread design with 0.8mm pitch for reduced surgical time.
  • Twist Type cutting edge for self-tapping ability and minimized bone resistance.
  • Micro thread technology with 0.2mm depth for enhanced initial fixation.
  • Tapered apex with dimensions tailored for stability in various implant sizes.

Description

Xcem XVT Tissue Level Dental Implants

Xcem XVT Tissue Level Dental Implant represents a pinnacle of innovation in dental implantology, providing practitioners with a state-of-the-art solution for achieving optimal gingival tissue contouring. Constructed from the robust and biocompatible Titanium 6AL 4V material, these implants ensure durability and compatibility. The self-cleansing SLA surface, characterized by Sandblasted, Large-grit, Acid-etched features, enhances surface area, promoting superior tissue-level contouring for improved stability. Featuring a 2.5 Hex indentation and an 11-degree Morse Taper connection, the implant ensures a secure fit during the placement process. The dual thread design, with a 0.8mm pitch, not only reduces surgical time but also contributes to efficient and stable implantation. The Twist Type cutting edge adds a self-tapping capability, minimizing bone resistance and optimizing the overall surgical experience.

Micro thread technology with a 0.2mm depth increases surface area and fosters a seamless connection with the main thread, improving initial fixation effects. With dimensions tailored for stability, the tapered apex further enhances the implant's overall performance. Available in various dimensions, the Xcem XVT Tissue Level Dental Implant series caters to diverse patient needs, making it a versatile and advanced choice for dental professionals committed to providing efficient, patient-friendly, and successful dental solutions.

Specification

  • Material: Titanium 6AL 4V
  • Surface: SLA (Sandblasted, Large-grit, Acid-etched)
  • Connection: 2.5 Hex indentation and 11-degree Morse Taper
  • Micro Thread: 0.2mm deep for increased surface area
  • Main Thread: Conical shape and lower deep thread for stability
  • Dual Thread: 0.8mm pitch, reducing surgery time
  • Apex: Dimension of D (fixture diameter) - 0.7mm, tapere

Packaging

  • 1 x XVT Tissue Level Dental Implant

Direction to use

  • Preoperative Assessment: Begin by thoroughly assessing the patient's oral health and ensuring the appropriateness of Xcem XVT Tissue Level Dental Implant for the specific case.
  • Patient Preparation: Administer local anesthesia and ensure proper isolation of the surgical site for aseptic conditions.
  • Incision and Flap Creation: Make a precise incision and create a flap to expose the implant site, maintaining adequate soft tissue coverage.
  • Osteotomy Preparation: Utilize the recommended surgical instruments to prepare the osteotomy site based on the chosen Xcem XVT implant dimensions.
  • Implant Placement: Carefully insert the Xcem XVT Tissue Level Dental Implant into the prepared osteotomy site, ensuring proper alignment and depth. Utilize the self-tapping ability for optimal placement.
  • Stability Check: Confirm the stability of the implant in the site. If stability is achieved, proceed with the next steps; otherwise, reassess and adjust as needed.
  • Closure: Suture the flap securely, ensuring tension-free closure. Follow proper wound closure techniques to promote optimal healing.
  • Postoperative Care: Provide postoperative instructions to the patient, including prescribed medications, oral hygiene guidelines, and follow-up appointments.
  • Restoration Phase: If immediate loading is planned, proceed with the restorative phase according to the treatment plan. If not, establish a timeline for subsequent restorative procedures.
  • Monitoring and Follow-up: Schedule regular follow-up appointments to monitor the healing process, assess osseointegration, and address any patient concerns.

Additional info

  • Country Of Origin: United Kingdom
  • Manufacturer: Xcem

Warranty

  • Warranty is not applicable for this product 

Product Related Questions

View full details