Types

W&H TE 95 Airotor Handpiece with its Ø 12.2 mm head size, strikes the perfect balance between maneuverability and visibility, allowing dentists to access hard-to-reach areas with ease. Powered by an 18-watt motor, this handpiece delivers consistent and reliable performance, ensuring efficient cutting and smooth operation. Operating at a speed range of 330,000 -1, it offers rapid rotation, enabling dentists to carry out procedures quickly and effectively. Designed to accommodate FG burs of Ø 1.6 mm (ISO 1797-1), it provides compatibility with commonly used burs in dental practice. The recommended operating pressure of 2.2 - 2.8 bar ensures optimal performance, and its ergonomic design enhances user comfort throughout procedures.

BC: 2 hole connection

RM: 4 hole connection

Features

  • Steel ball bearings
  • Single hole water spray
  • Push-button chucking system
  • Powerful and reliable performance
  • Non-LED 
  • Patented hygienic head system
  • Thermo washer disinfectable and sterilizable

Description

Specification

  • Head size: Ø 12.2 mm
  • Power: 18 Watt
  • Speed: 330,000 -1
  • For FG burs Ø 1.6 mm (ISO 1797-1)
  • Power : 18 watt
  • Recommended operating pressure : 2.2 - 2.8 bar

Packaging

  • 1  X Handpiece

Direction to use

Preparation

  • Ensure that the handpiece is clean and free from any debris or contaminants.
  • Connect the handpiece to the air tubing of the dental unit, ensuring a secure and proper connection.

Inserting the Bur:

  • Select a suitable FG bur with a diameter of Ø 1.6 mm (ISO 1797-1).
  • With the handpiece turned off, push the bur gently into the chuck and tighten it securely using the chuck key or the handpiece's built-in mechanism.
  • Ensure that the bur is seated properly and securely.

Adjusting Air Pressure:

  • Set the air pressure on the dental unit to the recommended range of 2.2 - 2.8 bar.
  • Proper air pressure ensures optimal performance and efficiency during the procedure.

Activation and Operation:

  • Press the handpiece's power button or foot control to activate the motor.
  • Hold the handpiece firmly but comfortably, maintaining a relaxed grip.
  • Position the handpiece in the desired location for the procedure, ensuring good visibility of the treatment area.

Performing the Procedure

  • Apply gentle pressure and control the handpiece's movements to achieve the desired outcome.
  • Follow the appropriate technique and guidelines specific to the dental procedure being performed.
  • Keep the handpiece moving smoothly and continuously to prevent overheating of the bur and ensure efficient cutting.

Cooling and Irrigation

  • If available, activate the water spray system on the dental unit to provide continuous cooling and lubrication to the bur during the procedure.
  • Monitor the water spray to ensure proper coverage and adjust it if necessary.

Completion and Maintenance

  • After completing the procedure, turn off the handpiece.
  • Remove the bur by loosening it with the chuck key or releasing it using the handpiece's built-in mechanism.
  • Clean and sterilize the handpiece according to the recommended procedures provided by the manufacturer.
  • Store the handpiece in a clean and dry environment to maintain its longevity and performance.

Additional info

Warranty

  • Manufacturer/Importer warranty of 6 months as applicable for this product.
  • Service and Warranty are handled by the manufacturer/importer directly for this product
  • Oralkart will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
  • Oralkart and the Buyer acknowledge that the Products purchased/used are a subject matter of original Manufacturer/Importer’s warranties only
  • Any or all claims in relation to returns and replacement shall be made to the concerned Manufacturer/Importer only and Oralkart may assist the customer in registering a request to get the Product replaced or serviced. 
  • The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be.

Product Related Questions

Question: What is the head size of the Alegra turbine handpiece?
Answer
: The Alegra turbine handpiece features a head size of Ø 12.2 mm, which provides an ideal balance between maneuverability and visibility for accessing hard-to-reach areas during dental procedures.

Question: What is the power output of the handpiece?
Answer:
The Alegra turbine handpiece is powered by an 18-watt motor, delivering consistent and reliable performance for efficient cutting and smooth operation.

Question: What is the speed range of the handpiece?
Answer
: The handpiece operates at a speed range of 330,000 -1, enabling rapid rotation and allowing dentists to carry out procedures quickly and effectively.

Question: What type of burs is compatible with the handpiece?
Answer
: The Alegra turbine handpiece is designed to accommodate FG burs with a diameter of Ø 1.6 mm (ISO 1797-1), which are commonly used in dental practice.

Question: What is the recommended operating pressure for the handpiece?
Answer
: The handpiece performs optimally within a recommended operating pressure range of 2.2 - 2.8 bar. Maintaining the recommended pressure ensures optimal performance during dental procedures.

Question: What are the available connection options for the handpiece?
Answer
: The Alegra turbine handpiece is available in two connection types: BC (2 hole connection) and RM (4 hole connection). Dentists can choose the appropriate connection type based on their dental unit configuration.

Question: Is the handpiece compatible with standard dental units?
Answer
: Yes, the Alegra turbine handpiece is designed to be compatible with standard dental units. Dentists can connect the handpiece to their dental unit using the appropriate connection type (BC or RM).

Question: Is the handpiece autoclavable?
Answer
: Yes, the handpiece is designed to be autoclavable. It can be safely sterilized using both steam and chemical autoclave methods, following the manufacturer's instructions.

Question: Is the handpiece comfortable to use?Answer: Yes, the Alegra turbine handpiece is ergonomically designed to enhance user comfort throughout dental procedures. Its balanced design and ergonomic grip contribute to a comfortable user experience.