Features

  • HP-1 motor with 2800 RPM for robust trimming power.
  • Two ball bearings ensure stability and durability during use.
  • Single-speed functionality for straightforward operation.
  • Continuous rating and equipped with a buffer for enhanced performance.
  • 12" Diamond Disc (Rough/Fine) from Indian craftsmanship for precise trimming.
  • Specifically designed for orthodontic and prosthodontic work.
  • Excludes suction, streamlining the trimming process without additional apparatus.
  • HP-1 motor with 2800 RPM for robust trimming power.
  • Two ball bearings ensure stability and durability during use.
  • Single-speed functionality for straightforward operation.
  • Continuous rating and equipped with a buffer for enhanced performance.
  • 12" Diamond Disc (Rough/Fine) from Indian craftsmanship for precise trimming.
  • Specifically designed for orthodontic and prosthodontic work.
  • Excludes suction, streamlining the trimming process without additional apparatus.

Description

The Unident Dental Dry/Wet Model Trimmer M-701 stands as a stalwart in the realm of orthodontics and prosthodontics, tailored to meet the demands of precision and efficiency in dental laboratories. Crafted with meticulous engineering, this model trimmer boasts a single-speed HP-1 motor, roaring at 2800 RPM, ensuring steadfast performance in heavy-duty tasks. Its robust design, fortified with two ball bearings, guarantees stability and endurance, enabling seamless execution of intricate dental work.

This trimmer is engineered for continuous usage, equipped with a buffer to enhance operational finesse. It comes accompanied by a formidable 12-inch diamond disc, available in both rough and fine variants, crafted in India, facilitating smooth and precise trimming of dental models. The absence of a suction mechanism streamlines its functionality, focusing on the core trimming process without unnecessary complexities.

For dental professionals seeking reliability and precision, the Unident Dental Dry/Wet Model Trimmer M-701 emerges as a trustworthy ally. Its availability through online purchasing platforms, coupled with its attributes designed for orthodontic and prosthodontic work, positions it as a valuable addition to any dental laboratory, meeting the exacting standards of efficiency and accuracy.

Specification

  • Model: M-701
  • Motor Type: HP-1
  • Motor Speed (RPM): 2800
  • Bearing Type:  Two Ball Bearings
  • Speed Control: Single Speed
  • Usage Rating: Continuous
  • Disc Diameter: 12 inches
  • Disc Type: Diamond (Rough/Fine)

Packaging

  • 1 x Accessories
  • 1 x Angle and plate
  • 1 x inlet pipe
  • 1 x outlet pipe
  • 1 x buffer

Direction to use

Setup and Preparation:

  • Place the trimmer on a stable surface in a well-ventilated area.
  • Ensure the power supply is compatible and stable.
  • Verify that the machine is switched off before plugging it in.

Preparation of Work Area:

  • Set up the water supply for wet trimming if needed. Ensure the water flow is appropriate and not excessive.

Mounting the Model:

  • Securely attach the dental model to the designated holder or platform using appropriate clamps or fixtures to prevent movement during trimming.

Adjusting the Diamond Disc:

  • Check the condition and placement of the diamond disc. Ensure it is properly mounted and securely in place.
  • Adjust the disc's height and angle if applicable for the desired trimming precision.

Switching On the Trimmer:

  • Turn on the power switch, ensuring all safety measures are in place.
  • For wet trimming, ensure the water flow is set to the appropriate level to aid in the trimming process.

Performing Trimming:

  • Gently bring the dental model into contact with the rotating diamond disc, gradually moving it across the surface to trim excess material.
  • Maintain steady, even pressure to achieve uniform trimming without applying excessive force.
  • For precise detailing, adjust the model's position as needed while the disc is in motion.

Monitoring and Finishing:

  • Regularly inspect the progress to achieve the desired shape and finish.
  • Avoid overheating by intermittently checking the disc and model temperature during prolonged use.

Switching Off and Clean-up:

  • After completing the trimming process, switch off the machine and disconnect the power supply.
  • Clean the trimmer, removing any debris or residue from the diamond disc and surrounding area.
  • Store the trimmer in a dry, safe place, ensuring it's ready for the next use.

Maintenance:

  • Regularly inspect the machine for any signs of wear or damage, and perform routine maintenance as per the manufacturer's instructions.

Additional info

Warranty

  • Manufacturer/Importer warranty of 1 Year against manufacturing defect
  • Service and Warranty are handled by the manufacturer/importer directly for this product

Product Related Questions

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
View full details