Features
Features
- HP-1 motor with 2800 RPM for robust trimming power.
- Two ball bearings ensure stability and durability during use.
- Single-speed functionality for straightforward operation.
- Continuous rating and equipped with a buffer for enhanced performance.
- 12" Diamond Disc (Rough/Fine) from Indian craftsmanship for precise trimming.
- Specifically designed for orthodontic and prosthodontic work.
- Excludes suction, streamlining the trimming process without additional apparatus.
- HP-1 motor with 2800 RPM for robust trimming power.
- Two ball bearings ensure stability and durability during use.
- Single-speed functionality for straightforward operation.
- Continuous rating and equipped with a buffer for enhanced performance.
- 12" Diamond Disc (Rough/Fine) from Indian craftsmanship for precise trimming.
- Specifically designed for orthodontic and prosthodontic work.
- Excludes suction, streamlining the trimming process without additional apparatus.
Description
Description
The Unident Dental Dry/Wet Model Trimmer M-701 stands as a stalwart in the realm of orthodontics and prosthodontics, tailored to meet the demands of precision and efficiency in dental laboratories. Crafted with meticulous engineering, this model trimmer boasts a single-speed HP-1 motor, roaring at 2800 RPM, ensuring steadfast performance in heavy-duty tasks. Its robust design, fortified with two ball bearings, guarantees stability and endurance, enabling seamless execution of intricate dental work.
This trimmer is engineered for continuous usage, equipped with a buffer to enhance operational finesse. It comes accompanied by a formidable 12-inch diamond disc, available in both rough and fine variants, crafted in India, facilitating smooth and precise trimming of dental models. The absence of a suction mechanism streamlines its functionality, focusing on the core trimming process without unnecessary complexities.
For dental professionals seeking reliability and precision, the Unident Dental Dry/Wet Model Trimmer M-701 emerges as a trustworthy ally. Its availability through online purchasing platforms, coupled with its attributes designed for orthodontic and prosthodontic work, positions it as a valuable addition to any dental laboratory, meeting the exacting standards of efficiency and accuracy.
Specification
Specification
- Model: M-701
- Motor Type: HP-1
- Motor Speed (RPM): 2800
- Bearing Type: Two Ball Bearings
- Speed Control: Single Speed
- Usage Rating: Continuous
- Disc Diameter: 12 inches
- Disc Type: Diamond (Rough/Fine)
Packaging
Packaging
- 1 x Accessories
- 1 x Angle and plate
- 1 x inlet pipe
- 1 x outlet pipe
- 1 x buffer
Direction to use
Direction to use
Setup and Preparation:
- Place the trimmer on a stable surface in a well-ventilated area.
- Ensure the power supply is compatible and stable.
- Verify that the machine is switched off before plugging it in.
Preparation of Work Area:
- Set up the water supply for wet trimming if needed. Ensure the water flow is appropriate and not excessive.
Mounting the Model:
- Securely attach the dental model to the designated holder or platform using appropriate clamps or fixtures to prevent movement during trimming.
Adjusting the Diamond Disc:
- Check the condition and placement of the diamond disc. Ensure it is properly mounted and securely in place.
- Adjust the disc's height and angle if applicable for the desired trimming precision.
Switching On the Trimmer:
- Turn on the power switch, ensuring all safety measures are in place.
- For wet trimming, ensure the water flow is set to the appropriate level to aid in the trimming process.
Performing Trimming:
- Gently bring the dental model into contact with the rotating diamond disc, gradually moving it across the surface to trim excess material.
- Maintain steady, even pressure to achieve uniform trimming without applying excessive force.
- For precise detailing, adjust the model's position as needed while the disc is in motion.
Monitoring and Finishing:
- Regularly inspect the progress to achieve the desired shape and finish.
- Avoid overheating by intermittently checking the disc and model temperature during prolonged use.
Switching Off and Clean-up:
- After completing the trimming process, switch off the machine and disconnect the power supply.
- Clean the trimmer, removing any debris or residue from the diamond disc and surrounding area.
- Store the trimmer in a dry, safe place, ensuring it's ready for the next use.
Maintenance:
- Regularly inspect the machine for any signs of wear or damage, and perform routine maintenance as per the manufacturer's instructions.