SafeEndo
SafeEndo GlassyLute Luting GIC
SafeEndo GlassyLute Luting GIC
Exclusive of GST
Couldn't load pickup availability
SafeEndo GlassyLute Restorative Luting Glass Ionomer Cement (GIC) is a dental product designed for reliable fixation in dental procedures. Its composition includes fluoro aluminosilicate glass powder, modifiers, and a liquid blend of polyacrylic acid, maelic acid, and tartaric acid. These components work synergistically to form a plastic paste with a film thickness of 10 µm upon mixing, ensuring precise application.
This cement boasts high biocompatibility with tooth tissues, offering a robust 185MPa strength and remarkable resistance to acid erosion. The polyacrylic acid facilitates chemical adhesion, ensuring a snug fit and excellent marginal integrity. Its fluorine-containing glass filler contributes to prolonged anticaries effects, enhancing patient outcomes.
SafeEndo GlassyLute is ideal for fixing crowns, dental bridgework, inlays, onlays, and orthodontic brackets. Its aesthetic properties make it suitable for metal-free restorations using high-strength ceramics, ensuring both functional and cosmetic excellence.
INDICATION
- For fixation of Crowns, Dental bridgework, Inlays , Onlays and Orthodontic
Brackets 
                      
                        
                        
                          Features
                        
                      
                    Features
- High Biocompatibility: Ensures compatibility with tooth tissues, reducing the risk of adverse reactions.
 - 185MPa Strength: Offers a robust level of strength, providing durable fixation for dental restorations.
 - Acid Erosion Resistance: Withstands acidic environments, maintaining its integrity and longevity.
 - Prolonged Anticaries Effect: Contains a fluorine-containing glass filler that accumulates and releases fluorine ions, contributing to long-lasting protection against cavities.
 
                      
                        
                        
                          Description
                        
                      
                    Description
                      
                        
                        
                          Specification
                        
                      
                    Specification
Composition:
- Fluoroaluminosilicate glass powder, Modificator
 - Polyacrylic acid, Maelic acid, Tartaric acid (Liquid)
 
Properties:
- High biocompatibility
 - 185MPa strength
 - Acid erosion resistance
 - Fluorine-containing glass filler for anticaries effect
 
Indications:
- Crowns
 - Dental bridgework
 - Inlays
 - Onlays
 - Orthodontic Brackets
 
Method of Use:
- Surface preparation
 - Mixing
 - Application
 
Storage:
- Temperature: 5°C to 25°C
 - Dry place, away from humidity
 - Shelf life: 3 years
 
                      
                        
                        
                          Packaging
                        
                      
                    Packaging
- 1 x Powder (35g bottle)
 - 1 x Liquid (25g bottle)
 - 1 x Measuring spoon
 - 1 x Mixing pad
 
                      
                        
                        
                          Direction to use
                        
                      
                    Direction to use
Surface Preparation:
- Ensure the tooth stump is prepared, cleaned, and dried.
 - Treat the tooth stump with conditioner using an applicator (cotton ball or sponge) for 10-15 seconds.
 - Thoroughly clean the cavity with water for 10-15 seconds and dry it slightly until a glossy surface is achieved. Do not over-dry.
 
Mixing:
- Shake the jar of powder before use without turning it over, tapping on your palm.
 - Mix the powder with the liquid on a mixing pad or glass plate using a plastic or metal spatula at room temperature (18-23°C).
 - Follow the recommended ratio of powder to liquid (1.4g powder to 1.0g liquid).
 - Mix for 30-45 seconds until a plastic consistency is obtained.
 
Application:
- Insert the material into the crown and fix it on the prepared tooth stump without over-compressing.
 - Patient should articulate and apply constant pressure until the material hardens (2.0-2.5 minutes).
 - Remove excess material and ensure a snug fit.
 
Post-Application:
- Advise the patient not to eat for 2 hours after application.
 - Clean metal instruments immediately after use.
 - Tightly close the container after each use.
 - In case of contact with eyes, skin, or oral tissues, remove the material immediately and wash with water.
 
                      
                        
                        
                          Additional info
                        
                      
                    Additional info
                      
                        
                        
                          Warranty
                        
                      
                    Warranty
- Warranty is not applicable for this product.
 
                      
                        
                        
                          Product Related Questions
                        
                      
                    Product Related Questions
Question: What is SafeEndo GlassyLute used for?
Answer: SafeEndo GlassyLute is used for fixation in dental procedures, including crowns, dental bridgework, inlays, onlays, and orthodontic brackets.
Question: What are the key properties of SafeEndo GlassyLute?
Answer: SafeEndo GlassyLute boasts high biocompatibility, 185 MPa strength, acid erosion resistance, and a prolonged anticaries effect.
Question: How long does SafeEndo GlassyLute take to harden?
Answer: SafeEndo GlassyLute typically hardens within 4-5 minutes after the start of mixing.
Question: What is the recommended storage condition for SafeEndo GlassyLute?
Answer: SafeEndo GlassyLute should be stored in a dry place at a temperature between 5°C and 25°C, away from humidity.
Question: Can SafeEndo GlassyLute be used on allergic patients?Answer: SafeEndo GlassyLute should be used with caution on allergic patients, and any drug idiosyncrasy should be considered before use.
Question: How long is the shelf life of SafeEndo GlassyLute?
Answer: The shelf life of SafeEndo GlassyLute is 3 years if stored correctly and used before the expiry date.
Question: What should be done in case of eye or skin contact with SafeEndo GlassyLute?
Answer: In case of contact with eyes, skin, or oral tissues, remove the material immediately and wash with water.
Question: Can SafeEndo GlassyLute be used for metal-free restorations?
Answer: Yes, SafeEndo GlassyLute's aesthetic properties make it suitable for fixation of metal-free crowns and bridges made of high-strength ceramics.