Skip to product information
1 of 8

OrthoMetric

OrthoMetric Ultra-P Self Ligating Bracket Kit + Arch Sequence

OrthoMetric Ultra-P Self Ligating Bracket Kit + Arch Sequence

Regular price Rs. 4,990.00
Regular price Sale price Rs. 4,990.00
Sale Sold out

Type

The OrthoMetric Ultra-P Self-Ligating Bracket Kit passive brackets with a unique closing mechanism that does not contact the archwires when in a passive state, resulting in very low friction ideal for sliding mechanics. The easy-to-manipulate opening and closing mechanism allows precise wire placement, increasing intervals between appointments and enhancing the efficiency of alignment and leveling phases, especially with thermo-activated wires. Additionally, the design accommodates ligatures for improved torque adjustments when needed, making these brackets particularly effective during the final phase of orthodontic treatment. This combination of features ensures optimal performance and patient comfort.

Features

  • Passive Bracket Design: The closing mechanism does not contact the archwires when passive, resulting in very low friction, ideal for sliding mechanics
  • Archwire Design: These archwires are designed to facilitate effective tooth movement throughout the four phases of orthodontic treatment, optimizing alignment and leveling processes
  • Easy-to-Use Mechanism: The opening and closing mechanism can be manipulated easily with an explorer, enhancing treatment efficiency
  • Compatibility with Thermoactivated Wires: Optimizes alignment and leveling phases, allowing for increased intervals between appointments
  • Elastic Ligature Use: The design accommodates ligatures for precise adjustments, especially during the final phase of treatment
  • Anatomical Base: Constructed with an 80-micron mesh spacing for excellent retention and laser markings for easy identification
  • Patient Comfort: Rounded corners enhance comfort during treatment
  • Comprehensive Kit: Includes one case and a self-ligating archwire sequence with six upper and lower pairs suitable for all treatment phases
  • Durable Material: Made from high-quality metal, ensuring longevity and reliable performance throughout orthodontic treatment

Description

Specification

  • Slot Size: MBT and Roth 0.022
  • Design: Self-Ligating
  • Material: Metal
  • Mechanism: Passive design with low friction; does not contact archwires
  • Opening/Closing: Easy to manipulate with an explorer; resistant to fatigue
  • Anatomical Base: 80-micron mesh for excellent retention
  • Ligature Compatibility: Allows precise adjustments in the final treatment phase

Archwire:

Material: Flexy NiTi Thermal 35º ALX

Sizes:

  • Upper and Lower: 0.014”
  • Upper and Lower: 0.018”
  • Upper and Lower: 0.014” x 0.025”
  • Upper and Lower: 0.017” x 0.025”

Material: Flexy NiTi Super Elastic ALX

Sizes:

  • Upper and Lower: 0.019” x 0.025”

Material: Orthometric SS Steel

Sizes:

  • Upper and Lower: 0.019” x 0.025”

Packaging

  • 1 x Ultra-p self-ligating bracket set of 20pcs

Archwire

Flexy NiTi Thermal 35º ALX

  • 2 x Upper and Lower 0.014”
  • 2 x Upper and Lower 0.018”
  • 2 x Upper and Lower 0.014” x 0.025”
  • 2 x Upper and Lower 0.017” x 0.025”

Flexy NiTi Super Elastic ALX

  • 2 x Upper and Lower 0.019” x 0.025”

Orthometric SS Steel

  • 2 x Upper and Lower 0.019” x 0.025”

Direction to use

Preparation:

  • Ensure the patient's teeth are clean and dry
  • Select the appropriate Ultra-P brackets and archwires based on the treatment plan

Bracket Placement:

  • Etching: Apply a phosphoric acid etchant to the enamel for 15-30 seconds, rinse, and dry
  • Primer: Apply a bonding agent to enhance adhesion
  • Positioning: Use the anatomical base of the bracket, ensuring it fits snugly against the tooth surface

Bonding:

  • Apply orthodontic adhesive to the bracket base
  • Press the bracket onto the tooth firmly and ensure proper alignment

Wire Insertion:

  • Insert the archwire into the bracket slot. The passive design allows for minimal friction, optimizing sliding mechanics.

Adjustments:

  • Use an explorer to manipulate the opening and closing mechanism of the brackets as needed
  • For precise adjustments, especially in the final phase, elastic ligatures can be added

Monitoring:

  • Regularly check brackets and wires during follow-up appointments to ensure effective treatment progression and make necessary adjustments

Additional info

  • Country of Origin: Brazil
  • Manufacturer: Orthometric

Warranty

  • Warranty is not applicable for this product.

Product Related Questions

Question: What are passive self-ligating brackets?
Answer:
Passive self-ligating brackets have a closing mechanism that does not contact the archwire when passive, resulting in very low friction ideal for sliding mechanics.

Question: What materials are the brackets made from?
Answer:
The brackets are constructed from high-quality self-ligating metal, ensuring durability and effective performance throughout treatment.

Question: What are the benefits of using these brackets?
Answer:
They provide a precise fit for archwires, increase intervals between appointments, and enhance alignment and leveling efficiency, especially with thermoactivated wires.

Question: How does the opening and closing mechanism work?
Answer:
The mechanism is easy to manipulate with an explorer, allowing for quick adjustments during treatment.

View full details