Types

Neoendo Neohybrid Rotary Files offer Unique off-centered rectangular cross section:

  • Asymmetric or swaggering movement. (2-point contact with the canal wall)
  • Minimal engagement between the file and canal dentin, effectively reducing taper-lock and screw-in forces as file moves inside the canal.
  • Less cross-sectional area creating higher flexibility for shaping severely curved canals and enhancing loading and augering of debris.

CTA Wire-Controlled Thermal Activation Wire:

  • Neoendo proprietary thermal process.
  • Improves flexibility while retaining cutting efficiency.
  • Gold, Blue, Gray color of the file as progressive heat treatment is applied.

Shorter Clinical Sequence:

  • The merit of efficient endodontics is now understood to be continuous and copious irrigation. Neohybrid, with its unique cross section and CTA wire technology allows for a shorter clinical sequence - it requires 2 files for most cases, so that you can allocate more time and energy to the pivotal irrigation.

 

Indications:

  • Used in the biomechanical preparation of the root canal during endodontic therapy.
  • For special cases like- severely curved canals.

 

Advantages:

  • 2-point contact with canal wall
  • Minimal engagement between files and canal dentin
  • Higher flexibility with cutting efficiency
  • Heat treated files
  • Shorter clinical sequence

Features

  • CTA Wire-Controlled Thermal Activation Wire.
  • Excellent flexibility.
  • Off-centred rectangular cross-section.
  • Sharp cutting flutes for better cutting efficiency.
  • Safety non-cutting tip minimizes risk of ledge formation.
  • High fracture resistance.
  • 2 files for most cases.
  • Calibrated length marking.

Description

Specification

  • Size #17 Taper 4% Length 25mm
  • Size #20 Taper 6% Length 25mm.

INDICATIONS

  • Used in the biomechanical preparation of the root canal during endodontic therapy.For special cases like- severly curved canals.

ADVANTAGES 

  • Point contact with canal wall Minimal engagement between files and canal dentin Higher flexibility with cutting efficiency Heat treated files Shorter clinical sequence.

Packaging

  • Pack of 6

Direction to use

Neohybrid Usage Protocol

  • Start by using a #15 size hand file with 2% taper, and the orifice opener rotary file.
  • Establish glide path using 17/4% file
  1. Narrow Canals: 20/4% or 20/6%
  2. Medium Canals: 25/4% or 25/6%
  3. Wide Canals: 30/4% or 30/6%
  • Prepare the access cavity and explore the canal using #8, #10 K-file or #12 Neoprobe File
  • Establish the working length with the help of Electronic Apex Locator (EAL)/ Radiograph
  • For obliterated, calcified or severely curved canals: start with #8, #10 K-File or use Neoendo Flex Glide Files till apex to achieve proper glide path
  • Use the file in brushing motion: take the file passively to the point of least resistance and brush out of the canal and repeat the procedure until working length is achieved
  • Always clean the cutting flutes after every few strokes, irrigate the canal and recapitulate with the K-File
  • Use Neohybrid files with gentle touch, never force the file and always use the recommended speed and torque settings.

Additional info

Warranty

Product Related Questions

Question: How does Neoendo Neohybrid contribute to a shorter clinical sequence?
Answer:
Neoendo Neohybrid requires only 2 files for most cases, streamlining the clinical sequence. This efficiency allows practitioners to allocate more time and energy to crucial aspects such as continuous and copious irrigation, contributing to effective endodontics.

Question: How does Neoendo Neohybrid address the challenges of severely curved canals?
Answer:
The off-centered rectangular cross-section, along with the CTA Wire technology, allows for 2-point contact with the canal wall. This minimizes engagement with canal dentin, providing higher flexibility and efficient loading and augering of debris in severely curved canals.

Question: What are the advantages of the CTA Wire-Controlled Thermal Activation Wire?
Answer:
The CTA Wire technology, implemented through a proprietary thermal process, improves flexibility without compromising cutting efficiency. The files are color-coded (Gold, Blue, Gray) to indicate progressive heat treatment, providing optimal performance.

Question: How does the off-centered rectangular cross-section benefit the user?
Answer:
The unique cross-section enables an asymmetric or swaggering movement with minimal engagement between the file and canal dentin. This design reduces taper-lock and screw-in forces, making it especially effective for shaping severely curved canals.

Question: What makes Neoendo Neohybrid Rotary Files unique?
Answer:
Neoendo Neohybrid Rotary Files stand out due to their off-centered rectangular cross-section, incorporating a CTA Wire-Controlled Thermal Activation Wire. This proprietary thermal process enhances flexibility while maintaining cutting efficiency.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
View full details