Skip to product information
1 of 2

IMPACT

Impact Internal Hex Dental Implant Standard Abutment - Angled

Impact Internal Hex Dental Implant Standard Abutment - Angled

Regular price Rs. 1,538.00
Regular price Rs. 2,500.00 Sale price Rs. 1,538.00
Sale Sold out

Types

The Impact Internal Hex Dental Implant Standard Abutment - Angled represents a pinnacle in dental implant technology, seamlessly combining precision and adaptability for optimal clinical outcomes. With an internal hex connection system, this abutment series is designed to simplify and enhance the restoration process. The key innovation lies in its angled configuration, offering practitioners unparalleled flexibility with options ranging from 15° to 45°, catering to diverse clinical scenarios.

This meticulously crafted abutment series addresses the intricacies of dental restorations with finesse. The varying collar heights, spanning 1mm to 4mm, ensure a tailored fit to individual anatomical considerations. The inclusion of anti-rotational capabilities not only bolsters stability but also underscores the series' commitment to enduring and reliable single implant restorations. The Impact Internal Hex Dental Implant Standard Abutment - Angled is a testament to simplicity meeting sophistication, providing a comprehensive solution for dental professionals across a spectrum of cases.

In the dynamic landscape of dental implantology, this series stands as a beacon of innovation, offering a harmonious blend of quality, ease-of-use, and adaptability. Elevate your clinical practice with the precision and versatility embodied in each abutment, ensuring a seamless and successful implant journey for both practitioners and patients alike.

Features

Description

Specification

  • Connection System: Internal Hex
  • Angled Variations: 15°, 25°, 35°, 45°
  • Collar Heights Available: 1mm, 2mm, 3mm, 4mm
  • Anti-Rotational Capabilities: Yes
  • Application Range: Simple to Complex

Packaging

  • 1 x Angled Abutment With Screw

Direction to use

Selection:

  • Choose the appropriate angled variation (15°, 25°, 35°, 45°) based on clinical requirements.
  • Select the collar height (1mm, 2mm, 3mm, 4mm) that best fits the patient's anatomical considerations.

Preparation:

  • Ensure a sterile environment and use proper aseptic techniques.
  • Confirm compatibility with the specific implant system being employed.

Implant Placement:

  • Follow standard implant placement procedures per manufacturer guidelines.
  • Use the internal hex connection for a secure fit.

Abutment Placement:

  • Attach the Impact Internal Hex Dental Implant Standard Abutment - Angled to the implant using the provided tools.
  • Align the abutment at the desired angle, ensuring proper engagement with the internal hex.

Tightening:

  • Use the recommended torque wrench and torque values provided by the manufacturer.
  • Ensure precise tightening to guarantee stability.

Restoration:

  • Proceed with the restorative process, taking advantage of the anti-rotational capabilities for enhanced longevity.

Post-Placement Care:

  • Instruct the patient on post-implant care and maintenance.
  • Schedule follow-up appointments as needed.

Documentation:

  • Maintain detailed records of the abutment used, including angle and collar height, for future reference.

Additional info

Warranty

Product Related Questions

Question: Can these abutments be used in immediate loading scenarios or compromised bone quality cases?
Answer:
Yes, the design features of these abutments, with their gradual compression and stability, make them suitable for immediate loading and challenging bone quality situations.

Question: What quality assurance measures ensure the reliability of these abutments?
Answer:
Each abutment undergoes rigorous testing for cleanliness and conformity, adhering to the highest international standards to ensure reliability and performance consistency.

Question: Are these abutments compatible with various implant systems available in the market?
Answer:
These abutments are designed to be compatible with a range of standard implant systems, enhancing their versatility and applicability.

Question: How do I determine the appropriate angle and collar height for a specific case?
Answer:
Angle and collar height selection are based on the patient's anatomy and procedural requirements. Consult with your dental professional to choose the most suitable option.

Question: What distinguishes the Impact Conical Dental Implant Standard Abutment - Angled from other abutments?
Answer:
These abutments feature a double progressive divergent thread design, optimizing bone compression and stability, especially in challenging dental scenarios.

Question: Is there a specific torque requirement for tightening the abutment?
Answer:
Yes, use the recommended torque values and torque wrench provided by the manufacturer to ensure precise and secure tightening.

Question: Can I use this abutment with any internal hex connection implant system?
Answer:
The abutment is compatible with a range of standard implants featuring an internal hex connection, ensuring broad applicability.

Question: Does the abutment feature anti-rotational capabilities?
Answer:
Yes, the Impact Internal Hex Dental Implant Standard Abutment - Angled is designed with anti-rotational features to enhance stability in single implant restorations.

Question: How do I choose the appropriate collar height for my patient?
Answer:
Select the collar height (1mm, 2mm, 3mm, or 4mm) based on the patient's anatomical requirements and the specifics of the restoration plan.

Question: What is the purpose of the angled design in the Impact Internal Hex Dental Implant Standard Abutment?
Answer:
The angled design provides versatility, allowing practitioners to choose from angles of 15°, 25°, 35°, and 45° to accommodate various clinical scenarios and anatomical considerations.

View full details