The Baldus Touch-70 Oxygen-Nitrous Oxide Mixer Unit with Encased Cart revolutionizes dental gas delivery. This advanced unit seamlessly blends oxygen and nitrous oxide, controlled by a user-friendly touch interface. The encased cart ensures mobility and convenience, making it an ergonomic solution for dental practices. Its precise gas mixing capabilities enhance patient comfort, while safety features prioritize clinician control. The unit's compact design, combined with cutting-edge technology, creates an efficient and space-saving solution for dental professionals, ensuring optimal gas administration during procedures. The Baldus Touch-70 represents a state-of-the-art approach to dental gas delivery systems. Timeless elegance combined with superior technology Baldus® Touch is the next-generation nitrous oxide device in the field of nitrous oxide sedation. Touch screens are indispensable in everyday life. The Baldus® Touch is the next generation of digital oxygen-nitrous oxide mixers with innovative menu functions and system settings.

  • Touchscreen - more usability and more possibilities
  • Automatic patient documentation and data export
  • Automatic rejection function
  • Max. Total flow 18l / min.
  • O2 flush button and complete failsafe system
  • Self-test and error memory
  • Automatic self-test
  • Precise thermal measurement method
  • More fun at work!
  • Made in Germany

Features

  • Digital Control: Controlled via a high-quality touchscreen for precise and convenient operation.
  • Selectable Mixing Ratios: Offers maximum flexibility with selectable mixing ratios of 50%, 60%, or 70% Nitrous Oxide.
  • CE Certified: Meets CE certification standards, ensuring compliance with regulatory requirements.
  • % Display: The mixing ratio can be precisely set and monitored through a percentage display.
  • One-Fingertip-Control: Automatic adjustment of the output flow for ease of use.
  • Oxygen Flush: Quick and effective oxygen flush available via a signal red button.
  • Premium Security Package: Enhanced safety features with acoustic and visual information signals.
  • Nitrolock: Automatic laughing gas stop in the event of oxygen failure, adding an extra layer of safety.
  • Self-Test Functions: Built-in self-test functions and watchdogs for continuous system monitoring.
  • Check Valve on the Bag-T: Ensures proper functioning and prevents backflow.
  • Rebreathing Substance: Includes a feature for rebreathing substance with an empty breathing bag.
  • Standard-Compliant Coding: Adheres to standard-compliant coding of gas types.
  • Versatile Installation: Can be installed in the All-in-One-Cart, cavity wall, or door of the work area.
  • US Patented: Holds a US Patent (No. 10,065,159 B2), highlighting its innovative design and technology.

Description

Specification

  • N2O limitation: 70%
  • Maximum Total Flow: 18 l / min
  • Security Package: Extended premium security package with acoustic and visual information signals
  • Connections: Connection for O2 demand mask,1 USB port
  • Input voltage: 110 / 230V AC 56-60HZ
  • Dimensions: 108 x 38.5 x 29 cm
  • Weight: 25 kg
  • Color: Matt white

Packaging

  • 1 x Baldus Touch nitrous oxide device
  • 3 x Disposable adult double nose masks blueberry
  • 3 x Disposable children's double nose masks strawberry
  • 1 x Complete tubing set with connectors
  • 1 x Baldus vacuum control block with inline flow measurement
  • 1 x Breathing bag 3 liters
  • 1 x Ultraslim cylinder pressure regulator O2 incl. Med. Fabric hose
  • 1 x Ultraslim cylinder pressure regulator N2O incl. Med. Fabric hose
  • 1 x All-in-One-Cart Ultra-Slim, fully clad trolley for Baldus Touch

Direction to use

Power On:

  • Ensure the unit is connected to a power source.
  • Power on the unit using the designated switch or button.

Digital Control:

  • Use the touchscreen interface to access the digital controls.
  • Select the desired mixing ratio (e.g., 50%, 60%, or 70% Nitrous Oxide).

Output Flow Adjustment:

  • Adjust the output flow according to the patient's needs. This can often be done with a one-fingertip-control feature.

Oxygen Flush:

  • In case of the need for an oxygen flush, use the designated button for a quick and controlled release of oxygen.

Security Features:

  • Familiarize yourself with the security features, such as self-test functions, watchdogs, and the Nitrolock automatic stop in case of oxygen failure.

Monitoring:

  • Keep an eye on the percentage display to ensure the accurate mixing ratio.

Emergency Procedures:

  • Understand emergency procedures and how to quickly and safely stop the flow of gases in case of unexpected situations.

Shutdown:

  • Properly shut down the unit after use.

Additional info

  • Country of Origin: Made in Germany

Warranty

  • Manufacturer/Importer warranty of 5 Year as applicable for this product.
  • Service and Warranty are handled by the manufacturer/importer directly for this product
  • Dentalkart will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
  • Dentalkart and the Buyer acknowledge that the Products purchased/used are a subject matter of original Manufacturer/Importer’s warranties only
  • Any or all claims in relation to returns and replacement shall be made to the concerned Manufacturer/Importer only and Dentalkart may assist the customer in registering a request to get the Product replaced or serviced. 
  • The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be.

Please click here to know about our return policy & how warranty is covered at Dentalkart

Product Related Questions

Question: What is the Baldus Touch-70 Oxygen-Nitrous Oxide Mixer Unit used for?
Answer:
The Baldus Touch-70 is used for mixing and delivering controlled concentrations of oxygen and nitrous oxide for dental sedation procedures.

Question: Does the Baldus Touch-70 have safety features?
Answer:
Yes, the unit is equipped with safety features, including acoustic and visual information signals for enhanced safety during sedation procedures.

Question: Is the mixing ratio adjustable on the Baldus Touch-70?
Answer:
Yes, the mixing ratio can be precisely set on the Baldus Touch-70 through the touchscreen controls.

Question: What is the maximum mixing ratio supported by the unit?
Answer:
The unit allows for selecting a maximum mixing ratio of 70% nitrous oxide, as per standard delivery.

Question: Does the unit have an oxygen flush feature?
Answer:
Yes, the Baldus Touch-70 features an oxygen flush button for a quick supply of 100% oxygen.