Apple Dental
Apple Dental Air-Motor Engine
Apple Dental Air-Motor Engine
Couldn't load pickup availability
Apple Dental Air-motor engines are the result of intensive research & studies by professionals to deliver the best of quality to dentists. Air-Motor is dental equipment that can be used in Dental clinics & minor surgical units in place of micromotors. They are air-driven motors as compared to electric-driven micromotors. It operates at a speed range of 18,000 to 21,000 rotations per minute (RPM) in both clockwise and counterclockwise directions. This speed range allows for efficient and precise cutting, grinding, or polishing during dental or surgical procedures.
Features
Features
- Powerful and Robust
- Compact and Ergonomic
- Quiet and Stable Operation
- Broad Speed Range
Description
Description
Specification
Specification
- Speed : 18,000–21,000 clockwise / counterclockwise
- Weight : 90gm
- Spray : External
Packaging
Packaging
Pack Of 1
Direction to use
Direction to use
- Prepare the Equipment: Ensure that the air motor engine, handpiece, and water source are properly connected and in good working condition. Confirm that the air supply is connected securely and that the water connection is intact.
- Adjust Speed and Direction: Set the desired speed and rotation direction on the air motor engine. Most models have adjustable speed controls and a switch to toggle between clockwise and counterclockwise rotation. Select the appropriate speed and direction based on the procedure and instrument being used.
- Connect the Handpiece: Attach the desired handpiece to the air motor engine. Depending on the procedure requirements, you can choose between a straight handpiece or a contra-angle handpiece. Make sure the connection is secure and properly aligned.
- Connect the Water Supply: Connect the external water source to the water connection on the air motor engine. This can be a water bottle or a water supply system connected to a dental unit or surgical console. Ensure that the water flow is properly regulated and adjusted to the desired level.
- Position the Instrument: Place the appropriate bur or surgical instrument in the handpiece. Ensure that it is securely fastened and properly aligned for the intended procedure.
- Activate the Air Motor Engine: Press the power button or trigger on the air motor engine to start the rotation. Depending on the model, you may need to control the speed using a foot pedal or the controls on the engine itself.
- Control Water Flow: Adjust the water flow control mechanism on the air motor engine or the separate water control unit, if applicable. Ensure that the water flow is sufficient to provide cooling and irrigation during the procedure. Adjust the flow rate as needed.
- Perform the Procedure: With the air motor engine activated and the water flow regulated, proceed with the dental or surgical procedure. Maintain a steady hand and control the instrument's movement to achieve the desired outcome. Monitor the water flow and adjust as necessary throughout the procedure.
- Clean and Maintain: After completing the procedure, turn off the air motor engine and disconnect the handpiece. Clean and sterilize the handpiece, air motor engine, and any associated components according to the manufacturer's instructions. Proper maintenance and sterilization are essential for the longevity and safe use of the equipment.
Additional info
Additional info
- Country of Origin: Made in PRC
- Manufacturer: Apple Dental
Warranty
Warranty
Product Related Questions
Product Related Questions
Question: Can it be used with contra angle handpiece to fit in unicorn dental chair ?
Answer: Yes, the Apple Dental Air-Motor Engine can indeed be used with a contra-angle handpiece to fit in the Unicorn dental chair. Contra-angle handpieces are commonly compatible with dental air motors, providing versatility and allowing for various dental procedures to be performed efficiently and effectively in the dental chair setup.
Question: Can the same micomotor contrangle be used with air motor ? Is there any risk of air emphysema?
Answer: Yes, the micromotor contra-angle can be utilized with the air motor, but caution is advised to avoid potential risks such as air emphysema. It is recommended to adhere to guidelines, follow proper operating procedures and ensure a secure fit to minimize any potential risks associated with air leakage and refrain from extensive use in surgical procedures for enhanced safety.
Question: Can this be used for guttering during surgical purpose ?
Answer: Yes, the Apple Dental Air-Motor Engine can be used for guttering during surgical purposes.
Question: Can I place implants with the Air-Motor Engine ?
Answer: No, the Apple Dental Air-Motor Engine is not suitable for placing implants. The implant placement procedure demands specific speed and torque settings at various steps, which the Air-Motor Engine may not provide. For implant placement, it is recommended to use a dedicated implant motor engine designed to meet the specific requirements of implant procedures, ensuring precise control over speed and torque.
Question: How does an air motor engine with an external water connection work?
Answer: The air motor engine is powered by compressed air and provides rotational power to dental burs or surgical instruments. The external water connection supplies a continuous flow of water to cool the working area and remove debris during procedures.
Question: What is the purpose of the external water connection?
Answer: The external water connection serves two main purposes: cooling and irrigation. The water flow cools the bur or instrument, preventing overheating, while also providing irrigation to wash away debris and maintain a clear field of view.
Question:Can I use both straight and contra-angle handpieces with this air motor engine?
Answer: Yes, an air motor engine compatible with both straight and contra-angle handpieces allows for versatile use in different dental and surgical procedures. Straight handpieces are typically used for general procedures, while contra-angle handpieces are useful for accessing hard-to-reach areas or performing oral surgeries.
Question: How do I adjust the speed and rotation direction of the air motor engine?
Answer: Most air motor engines have adjustable speed controls and a switch to toggle between clockwise and counterclockwise rotation. Consult the user manual or manufacturer's instructions for specific details on adjusting speed and rotation direction for your particular model.
Question: What is the recommended speed range for the air motor engine?
Answer: The recommended speed range for an air motor engine typically falls between 18,000 and 21,000 rotations per minute (RPM). However, it's important to refer to the manufacturer's guidelines for your specific device to ensure proper usage.
Share






