adin
Adin RS Open Tray Transfer TMA Screw (RS5008)
Adin RS Open Tray Transfer TMA Screw (RS5008)
Couldn't load pickup availability
The Adin RS Open Tray Transfer TMA Screw (RS5008) is a critical component in dental implant procedures, designed to facilitate accurate impressions and transfer of implant positions to the dental laboratory. This screw is specifically engineered for use with the Trans Mucosal Abutment (TMA) system, ensuring a precise and reliable fit. The RS5008 is utilized during the open tray impression technique, which allows for direct visualization and easy access during the impression-taking process, enhancing the accuracy of the transfer. This screw's design ensures stability and prevents micromovements, which is crucial for maintaining the exact position of the implant during the impression process. The RS5008 is compatible with various impression materials, making it versatile for different clinical scenarios. By using the Adin RS Open Tray Transfer TMA Screw, dental professionals can achieve high-precision impressions, leading to better-fitting restorations and improved patient outcomes. Its robust construction ensures durability and reliability, making it an essential tool in modern implant dentistry.
Features
Features
- High-Quality Material: Made from titanium grade 5 for superior biocompatibility and durability
- Precision Engineering: Designed to facilitate accurate transfer of implant positions
- Open Tray Design: Allows for easy removal of the impression coping and screw as a single unit, minimizing the risk of distortion
- Compatibility: Specifically designed to work with Adin's TMA system, ensuring a secure fit
- Enhanced Workflow: Simplifies the impression-taking process, especially in complex cases with multiple implants
- Durability: Provides long-lasting performance even in challenging oral environments
- Ease of Use: User-friendly design that allows for straightforward attachment and removal
- Secure Attachment: Ensures stable and reliable connection of the impression coping to the implant
- Accurate Impressions: Contributes to the successful planning and execution of implant restorations by capturing precise implant positions
- Versatile Application: Compatible with various impression materials, enhancing its utility in different clinical settings
Description
Description
Specification
Specification
- Type: Open Tray Transfer Screw for TMA System
- Material: Titanium Grade 5
- Length: 14mm
- Diameter: 2.1mm
- Functionality: Designed to secure open tray impression copings for accurate impression transfer in dental implant procedures using the TMA system
- Compatibility: Specifically compatible with Adin's TMA implant system
- Recommended Insertion Torque: Up to 15 Ncm
Packaging
Packaging
- 1 x RS open tray transfer TMA screw
Direction to use
Direction to use
Preparation:
- Ensure that the implant site is clean and free of debris
- Have the necessary tools and materials ready, including the RS5008 screw, the open tray impression coping, and the open tray
Attachment:
- Attach the open tray impression coping to the implant using the RS5008 screw
- Ensure the coping is securely attached and properly aligned with the implant
Impression Taking:
- Place the open tray over the coping, ensuring it fits snugly without interference
- Fill the tray with impression material, covering the coping and surrounding areas
Removal:
- Allow the impression material to set according to the manufacturer’s instructions
- Once set, carefully remove the tray, ensuring the coping and RS5008 screw come out together as a single unit
Transfer to Laboratory:
- Send the impression, with the attached coping and screw, to the dental laboratory
- The lab will use this accurate impression to create the restoration
Verification:
- Upon receiving the final restoration, verify the fit and alignment using the same coping and screw if needed
- Make any necessary adjustments before final placement in the patient's mouth
Final Placement:
- Once satisfied with the fit, proceed with the final placement of the restoration
Additional info
Additional info
- Country of Origin: Israel
- Manufacturer: Adin
Warranty
Warranty
- Warranty is not applicable for this product.
Product Related Questions
Product Related Questions
Question : What is the Adin RS Open Tray Transfer TMA Screw (RS5008) used for?
Answer: It is used to secure impression copings to implants for accurate open tray impressions.
Question : Can the Adin RS Open Tray Transfer TMA Screw be used with different types of impression materials?
Answer: Yes, it is compatible with various impression materials commonly used in dental procedures.
Question : What are the advantages of using the Adin RS Open Tray Transfer TMA Screw?
Answer: It ensures precise transfer of implant positions and reduces the risk of impression distortion.
Question : How does the open tray design benefit the impression process?
Answer: The open tray design allows for easy removal of the impression coping and screw as a single unit, minimizing the risk of distortion.
Question : What material is the Adin RS Open Tray Transfer TMA Screw made from?
Answer: The Adin RS Open Tray Transfer TMA Screw is made from high-quality titanium grade 5.
Share





