adin
Adin RS Flat Connection Implant Replica (FC5737)
Adin RS Flat Connection Implant Replica (FC5737)
Couldn't load pickup availability
The Adin RS Flat Connection Implant Replica (FC5737) is a high-precision component used in dental implantology to accurately replicate the dimensions and characteristics of the actual implant during the prosthetic planning and fabrication phases. This implant replica is specifically designed to be used in conjunction with Adin's RS Flat Connection implants, ensuring seamless compatibility and reliable results. Constructed to provide an exact match to the original implant, the FC5737 facilitates the creation of precise working models. This replica allows dental technicians and clinicians to visualize and plan the final prosthetic restoration accurately. Its robust design ensures durability and stability throughout the modeling and fabrication processes.
Features
Features
- High Precision: Accurately replicates the dimensions and characteristics of the actual implant.
- Compatibility: Specifically designed for use with Adin's RS Flat Connection implants.
- Durable Construction: Ensures stability and longevity during the modeling and fabrication processes.
- Exact Fit: Facilitates precise positioning in the impression material for accurate working models.
- Enhanced Planning: Enables detailed prosthetic planning and fabrication for optimal results.
- Reliable Results: Helps achieve accurate final prosthetic restorations, reducing the need for adjustments.
- User-Friendly: Easy to use within the workflow of dental technicians and clinicians.
- Seamless Integration: Integrates smoothly into the prosthetic workflow, from impression to final placement.
- Material Quality: Made from high-quality materials to ensure performance and reliability.
- Improved Outcomes: Contributes to better clinical outcomes and higher patient satisfaction by ensuring precise prosthetic fits.
Description
Description
Specification
Specification
- Type: Flat Connection Implant Replica
- Material: Stainless Steel
- Length: 11.5mm
- Design: Mimics the dimensions and features of flat connection implants
- Implant system: RS implant system
- Functionality: Accurately replicates flat connection implants for model creation
Packaging
Packaging
- 1 x Flat connection implant replica
Direction to use
Direction to use
Preparation:
- Ensure you have the necessary tools and materials ready, including the impression tray, impression material, and the FC5737 implant replica
- Verify the implant site is clean and properly healed if post-surgery
Impression Taking:
- Place the impression tray in the patient’s mouth, ensuring it fits comfortably
- Apply the impression material to the tray, ensuring even coverage
- Insert the tray into the patient’s mouth, pressing gently to ensure the material covers the implant site and surrounding areas
- Allow the impression material to be set according to the manufacturer’s instructions
Insertion of Implant Replica:
- Once the impression material has set, carefully remove the tray from the patient's mouth
- Insert the FC5737 implant replica into the impression material at the exact location of the implant
- Ensure the replica is positioned correctly and securely to mimic the actual implant placement
Model Creation:
- Pour the dental stone or another suitable material into the impression to create the working model
- Allow the model to set completely before removing it from the impression tray
Verification:
- Check the working model to ensure the implant replica is accurately positioned and secure
- Verify that the model replicates the patient’s oral anatomy and implant site accurately
Prosthetic Planning and Fabrication:
- Use the working model with the implant replica to plan and fabricate the prosthetic restoration
- Ensure all components fit precisely on the replica to guarantee an accurate final restoration
Final Placement:
- Use the model with the implant replica for trial fittings of the prosthetic components
- Once satisfied with the fit and aesthetics, proceed with the final placement in the patient’s mouth
Post-Procedure:
- Provide the patient with aftercare instructions to ensure proper healing and maintenance
- Schedule follow-up appointments to monitor the implant site and prosthetic restoration
Additional info
Additional info
- Country of Origin: Israel
- Manufacturer: Adin
Warranty
Warranty
- Warranty is not applicable for this product.
Product Related Questions
Product Related Questions
Question : What is the primary use of the Adin RS Flat Connection Implant Replica?
Answer: It is used to create precise working models that accurately replicate the position of dental implants for prosthetic dentistry.
Question : Can this implant replica be used with both intraoral and desktop scanners?
Answer: No, the RS Flat Connection Implant Replica is not designed for use with digital scanners. It is used for creating physical working models for laboratory use.
Question : What are the benefits of using the RS Flat Connection Implant Replica?
Answer: It provides a reliable method for transferring implant positions to the laboratory, improving the accuracy and quality of prosthetic restorations.
Question : Is the RS Flat Connection Implant Replica compatible with all implant systems?
Answer: It is specifically designed to work with Adin's RS Flat Connection implant system.
Share



