The Adin RS Flat Connection Centering Ring (FC6018) is a critical component in dental implant systems, designed to ensure proper alignment and stability between the implant and the abutment. Constructed from high-quality materials, this centering ring plays a vital role in achieving accurate prosthetic connections.

The centering ring serves several key purposes:

  • Alignment: It ensures precise alignment of the abutment with the implant, facilitating accurate placement and reducing the risk of misalignment during restoration.
  • Stability: By securely fitting the abutment onto the implant platform, the centering ring enhances overall stability, contributing to the long-term success of the implant.
  • Reduction of Micro-Movements: The centering ring minimizes micro-movements between the implant and abutment, promoting better osseointegration and longevity of the implant.
  • Versatility: The centering ring is compatible with various abutment types, including flat and castable abutments, accommodating different prosthetic needs and design preferences.

This versatile and essential component ensures reliable performance and optimal outcomes in dental implant restorations, making it a valuable tool for dental professionals.

Features

  • Precise Alignment: Ensures accurate alignment between the implant and abutment, reducing the risk of misplacement
  • Enhanced Stability: Provides a secure fit, enhancing the stability of the implant-abutment connection
  • Micro-Movement Reduction: Minimizes micro-movements to promote better osseointegration and implant longevity
  • Versatile Compatibility: Compatible with various abutment types, including flat and castable abutments
  • Durable Construction: Made from high-quality materials, ensuring long-lasting performance in the oral environment
  • Easy Integration: Designed to integrate seamlessly with Adin's RS Flat Connection implant system for streamlined workflows
  • Improved Clinical Outcomes: Enhances the overall success of implant restorations by providing reliable and precise connections
  • User-Friendly Design: Simplifies the process of aligning and securing abutments, making it easier for dental professionals

Description

Specification

  • Type: Centering Ring
  • Length: 3.8 mm
  • Diameter: 4.5 mm
  • Rotational Height: 0.6mm
  • Connection Type: Flat interface for secure implant-abutment alignment
  • Compatibility: Works with various abutment types in implant systems
  • Function: Ensures precise alignment and stability, minimizing micro-movements

Packaging

  • 1 x Centering ring

Direction to use

Preparation:

  • Ensure that the implant site is clean and free of any debris
  • Verify that all components, including the centering ring, abutment, and implant, are compatible and ready for use

Implant Placement:

  • Place the dental implant into the prepared site according to standard implant placement procedures

Centering Ring Placement:

  • Carefully position the centering ring onto the implant platform
  • Ensure that the ring is seated correctly, aligning it precisely with the implant's flat connection

Abutment Alignment:

  • Select the appropriate abutment for the restoration
  • Align the abutment with the centering ring, ensuring that it fits securely into place

Securing the Abutment:

  • Use the recommended retaining screw to secure the abutment to the implant through the centering ring
  • Tighten the screw to the specified torque setting, ensuring a stable and secure connection

Verification:

  • Check the alignment and stability of the abutment and centering ring
  • Verify that there are no gaps or misalignments between the components

Final Adjustments:

  • Make any necessary adjustments to ensure proper fit and function
  • Confirm that the assembly is stable and ready for the final prosthetic restoration

Prosthetic Restoration:

  • Proceed with the fabrication and placement of the prosthetic restoration as per the treatment plan
  • Ensure that the restoration fits securely and comfortably over the abutment

Post-Procedure Care:

  • Provide the patient with appropriate post-procedure care instructions
  • Schedule follow-up appointments to monitor the success and stability of the implant restoration

Additional info

  • Country of Origin: Israel
  • Manufacturer: Adin

Warranty

  • Warranty is not applicable for this product.

Product Related Questions

Question : What is the purpose of the centering ring?
Answer:
The centering ring ensures precise alignment and stability between the implant and the abutment, reducing micro-movements and promoting better osseointegration.

Question : How does the centering ring affect osseointegration?
Answer:
By minimizing micro-movements between the implant and abutment, it promotes better osseointegration and longevity of the implant.

Question : What types of implants and abutments is the centering ring compatible with?
Answer:
The centering ring is compatible with RS Flat Connection implants and abutments, including various prosthetic designs.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
View full details