adin
Adin RS Closed Tray Transfer Screw (RS3425)
Adin RS Closed Tray Transfer Screw (RS3425)
Couldn't load pickup availability
The Adin RS Closed Tray Transfer Screw (RS3425) is designed to work in conjunction with the RS Scan Body 10mm for capturing accurate digital impressions in dental implant procedures. This closed tray transfer screw facilitates the direct transfer of the implant position to the scan body, ensuring precision and reliability during the digital impression-taking process.Constructed from high-quality titanium grade 5, the RS3425 offers excellent biocompatibility and durability, making it suitable for long-term use in the oral environment. Its closed tray design minimizes the risk of distortion during impression removal, which is crucial for achieving accurate results, particularly in complex cases.The RS Closed Tray Transfer Screw is specifically compatible with Adin RS implant systems, ensuring a secure fit and optimal performance when used with the RS Scan Body 10mm. By providing a reliable method for capturing digital impressions, the RS3425 contributes to the successful planning and execution of implant restorations, ultimately enhancing patient outcomes in digital dentistry. Its ease of use and precision make it an essential tool for dental professionals.
Features
Features
- Compatibility: Specifically designed to be compatible with the RS Scan Body 10mm, enhancing versatility
- Precision: Ensures accurate transfer of implant position to the dental laboratory
- Stability: Provides a secure and stable fit during the impression-taking process
- Ease of Use: Facilitates the closed tray impression technique efficiently
- Reliability: Constructed for reliable performance during dental implant procedures
- Integration: Seamlessly integrates into digital workflows for modern dental practices
- Versatility: Suitable for use with various impression materials
- Durability: Made to withstand the rigors of clinical use without compromising accuracy
- Enhanced Accuracy: Helps in achieving detailed and precise impressions
- Optimal Restoration: Contributes to improved restoration outcomes in implant dentistry
Description
Description
Specification
Specification
- Type: Closed Tray Transfer Screw
- Material: Titanium Grade 5
- Length: 12.2mm
- Diameter: 2.1mm
- Functionality: Facilitates accurate impression-transfer for implant positioning using a closed tray technique
- Compatibility: Specifically designed for use with for RS Scan Body 10mm
- Design: Closed tray design minimizes distortion during impression removal
- Recommended Insertion Torque: Up to 15 Ncm
Packaging
Packaging
- 1 x RS closed tray transfer screw
Direction to use
Direction to use
Preparation
- Attach the RS3425 closed tray transfer screw to the implant fixture in the patient's mouth using the recommended torque of up to 15 Ncm
- Ensure the implant is properly cleaned and dried before proceeding
Placing the Scan Body
- Remove the protective cap from the RS Scan Body 10mm
- Place the scan body over the transfer screw, aligning the internal connection. Apply gentle pressure to fully seat it.
- Verify the scan body is securely engaged with the transfer screw and does not rotate or move
Capturing the Digital Impression
- Use your preferred intraoral scanning device to capture the digital impression with the transfer screw and scan body in place
- Ensure the entire scan body and surrounding tissues are captured in the scan for accurate impression transfer
- Avoid excessive pressure or movement of the scan body during scanning to prevent distortion
Removing the Impression
- After scanning is complete, gently remove the scan body and transfer screw together as a single unit from the patient's mouth
- Visually inspect the impression to ensure no distortion occurred during removal
- Proceed with the digital workflow for designing and fabricating the implant restoration
Additional info
Additional info
- Country of Origin: Israel
- Manufacturer: Adin
Warranty
Warranty
- Warranty is not applicable for this product.
Product Related Questions
Product Related Questions
Question : What is the purpose of using the RS3425 screw with the RS Scan Body 10mm?
Answer: The RS3425 closed tray transfer screw is designed to work in conjunction with the RS Scan Body 10mm to capture accurate digital impressions for dental implants using a closed tray technique.
Question : What materials are compatible with the RS3425 screw?
Answer: The RS3425 screw is compatible with titanium grade 5 components, particularly the RS Scan Body 10mm and other Adin prosthetic components.
Question : Is the RS3425 screw compatible with all implant systems?
Answer: No, the RS3425 screw is specifically designed for use with Adin RS implant systems for compatibility and performance.
Question : Why is the closed tray design important?
Answer: The closed tray design minimizes distortion during impression removal, ensuring accurate transfer of the implant position to the digital model.
Share



