Adin CloseFit UNP Implant Conical Cover Screw (UNP0073)
Adin CloseFit UNP Implant Conical Cover Screw (UNP0073)
The Adin CloseFit UNP Implant Conical Cover Screw (UNP0073) is a crucial component in dental implant procedures, designed to protect the internal structure of the implant during the healing phase. This screw fits securely over the implant, providing a protective barrier against debris and bacteria, which is essential for promoting optimal healing and osseointegration. Its conical shape ensures a tight seal with the implant, preventing any unwanted movement or contamination. Constructed from high-quality materials, the UNP Conical Cover Screw offers excellent durability and biocompatibility, making it suitable for use in various oral environments. It is designed for easy insertion and removal, allowing for a smooth workflow during both the surgical and prosthetic phases of treatment. By safeguarding the implant site during healing, the Adin CloseFit UNP Implant Conical Cover Screw plays a vital role in the success of implant procedures, ensuring a stable foundation for future restorative work and enhancing overall patient outcomes. Its compatibility with the CloseFit system ensures seamless integration and reliable performance.
Features
Features
- Protective Barrier: Provides a secure barrier over the implant during the healing phase, preventing debris and bacteria from entering the implant site
- Conical Shape: Ensures a tight and stable seal with the implant, reducing the risk of contamination and unwanted movement
- High Biocompatibility: Made from high-quality, biocompatible materials, ensuring safety and compatibility with the oral environment
- Durability: Constructed to withstand the conditions of the oral cavity, maintaining its integrity throughout the healing period
- Easy Handling: Designed for smooth and straightforward insertion and removal, facilitating a seamless workflow for dental professionals
- Secure Fit: Precision-engineered to fit snugly over the implant, providing reliable protection and stability
Description
Description
Specification
Specification
- Type: Implant Cover Screw
- Material: Biocompatible material (specific type not mentioned)
- Implant system: Closefit UNP
- Recommended Torque: 15 (Ncm)
- Design: Conical shape for optimal fit and stability
- Functionality: Protects the implant site during the healing phase
- Compatibility: Specifically designed for CloseFit UNP implant systems
- Dimension: L:4.9mm , Outer D: 2.3mm, Inner D: 2.27mm
Packaging
Packaging
- 1 x Implant cover screw
Direction to use
Direction to use
Prepare the Implant Site:
- Ensure the implant is properly placed and the site is clean and free from debris
Select the Appropriate Cover Screw:
- Choose the correct length of the conical cover screw based on the specific clinical requirements
Insert the Cover Screw:
- Carefully position the cover screw over the implant
- Use a compatible driver to gently screw the cover into place. Ensure it is seated securely without over-tightening
Verify the Fit:
- Check the fit of the cover screw to ensure it forms a tight seal with the implant
- Confirm that there is no movement and the screw is stable
Monitor the Healing Process:
- Allow the cover screw to remain in place during the healing period, typically a few weeks to several months, depending on the treatment plan
- Regularly check the implant site for any signs of infection or complications
Remove the Cover Screw:
- Once the healing period is complete and the site is ready for the next stage of the procedure, use the driver to carefully unscrew and remove the cover screw
- Proceed with the placement of the abutment and the final prosthetic restoration as planned
Post-Procedure Care:
- Provide the patient with instructions on maintaining oral hygiene around the implant site
- Schedule follow-up appointments to monitor the healing progress and ensure the implant's stability
Additional info
Additional info
- Country of Origin: Israel
- Manufacturer: Adin
Warranty
Warranty
- Warranty is not applicable for this product.
Product Related Questions
Product Related Questions
Question : What is the primary use of the UNP Conical Cover Screw?
Answer: The UNP Conical Cover Screw is used to protect the implant site during the healing phase after dental implant placement.
Question : How long should the cover screw remain in place?
Answer: It should remain in place until the healing period is complete and the abutment or prosthesis is ready to be attached, typically a few weeks to a few months.
Question : Can the cover screw be reused?
Answer: No, the cover screw is intended for single-use only to ensure sterility and integrity.
Question : Is the UNP Conical Cover Screw compatible with all implant systems?
Answer: No, it is specifically designed for use with the Adin CloseFit UNP Implant System.