Skip to product information
1 of 4

adin

Adin Closefit RP Open Tray Transfer Screw

Adin Closefit RP Open Tray Transfer Screw

Regular price Rs. 554.00
Regular price Rs. 692.00 Sale price Rs. 554.00
Sale Sold out

Types

The Adin Closefit RP Open Tray Transfer Screw is an essential component in dental implantology, specifically designed to facilitate accurate impressions for the precise transfer of implant positions. It is engineered to work seamlessly with the Adin Closefit RP implant system, ensuring reliable and detailed impression-taking for prosthetic restorations. This transfer screw is used in conjunction with an open tray technique, which allows for direct visualization and access during the impression process. This feature is particularly beneficial when dealing with multiple implants or complex cases, as it enhances accuracy and efficiency. The screw's design ensures it fits securely and can be easily handled during clinical procedures, providing a stable connection between the impression coping and the implant. This ensures that the implant's exact position is accurately replicated in the dental laboratory, contributing to successful and precise prosthetic outcomes. The Adin Closefit RP Open Tray Transfer Screw is a vital tool for dental professionals aiming for precision and reliability in their implant procedures.

Features

  • Precise Fit: Engineered for secure and accurate positioning within the implant system.
  • Enhanced Accuracy: Facilitates detailed and reliable impression-taking for prosthetic restorations.
  • Open Tray Design: Allows for direct visualization and access during the impression process.
  • Compatibility: Designed to work seamlessly with the Adin Closefit RP implant system.
  • Easy Handling: Ensures stable connection and ease of use during clinical procedures.
  • Stable Connection: Provides a secure link between the impression coping and the implant.
  • Versatile Use: Suitable for multiple implants and complex cases.
  • Durability: Built to withstand clinical handling and provide consistent performance.
  • Reliable Transfer: Ensures accurate replication of implant positions in the dental laboratory.
  • Prosthetic Precision: Contributes to successful and precise prosthetic outcomes.

Description

Specification

  • Type: Open Tray Transfer Screw
  • Dimension: Short - D-3.10mm L-24mm, Long - D-3.10mm L-28mm
  • Functionality: Facilitates accurate impression-transfer for implant positioning
  • Compatibility: Specifically designed for use with CloseFit RP implant systems
  • Design: Open tray design allows for easy access and minimizes distortion during impression removal

Packaging

  • 1 x Closefit RP open tray transfer screw

Direction to use

Preparation:

  • Ensure the implant site is clean and dry
  • Prepare the necessary tools and materials, including the open tray impression tray and impression material

Positioning the Transfer Screw:

  • Attach the Adin Closefit RP Open Tray Transfer Screw to the implant in the patient's mouth
  • Ensure the screw is securely connected and properly seated

Tray Placement:

  • Select an appropriate open tray impression tray that fits comfortably over the implant site
  • Position the tray in the patient's mouth, ensuring it aligns with the transfer screw

Impression Material Application:

  • Apply the impression material into the open tray, covering the transfer screw and surrounding area
  • Make sure the material flows around the transfer screw to capture a detailed impression

Taking the Impression:

  • Allow the impression material to set according to the manufacturer's instructions
  • Carefully remove the open tray from the patient's mouth, ensuring the transfer screw remains in place within the impression

Removing the Transfer Screw:

  • Once the impression is taken, gently unscrew the Adin Closefit RP Open Tray Transfer Screw from the implant
  • Leave the transfer screw embedded in the impression material

Sending to the Laboratory:

  • Send the impression with the embedded transfer screw to the dental laboratory
  • Ensure all relevant patient and implant information is included for accurate processing

Restoration Process:

  • The dental laboratory will use the impression to create a precise model of the implant site
  • The transfer screw will help in accurately replicating the implant position for prosthetic fabrication

Additional info

  • Country of Origin: Israel
  • Manufacturer: Adin

Warranty

  • Warranty is not applicable for this product.

Product Related Questions

Question : What is the Adin Closefit RP Open Tray Transfer Screw used for?
Answer:
It is used to facilitate accurate transfer of implant positions to the dental laboratory for precise prosthetic fabrication.

Question : Are there specific sterilization guidelines for the transfer screw?
Answer:
Yes, follow standard sterilization protocols for dental instruments before use to ensure it is free from contaminants.

Question : How do I know if the transfer screw is properly seated?
Answer:
The transfer screw should be seated firmly with no movement, and you should feel a secure fit when tightened.

Question : How is the transfer screw secured in the implant?
Answer:
The transfer screw is securely fastened into the implant using a corresponding driver, ensuring stable and precise positioning during the impression process.

Question : Is the Adin Closefit RP Open Tray Transfer Screw compatible with all RP implants?Answer: Yes, it is specifically designed for use with Closefit RP implants.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
View full details