Skip to product information
1 of 4

adin

Adin Closefit NP Retrieval Screw for Abutments (NP0014)

Adin Closefit NP Retrieval Screw for Abutments (NP0014)

Regular price Rs. 567.00
Regular price Rs. 708.00 Sale price Rs. 567.00
Sale Sold out

The Adin Closefit NP Retrieval Screw for Abutments (NP0014) is specifically designed for the efficient retrieval of abutments from dental implants. This specialized screw enables dental professionals to easily and safely remove abutments during procedures, such as adjustments or replacements. The NP0014 features a precise design that ensures a secure fit with the abutments, facilitating reliable engagement and minimizing the risk of damage during retrieval. With a recommended insertion torque of up to 50 Ncm, it is engineered to withstand the forces encountered during abutment removal. This retrieval screw is an essential tool for dental practitioners, enhancing workflow efficiency and ensuring the integrity of both the implant and abutment during restorative procedures. Its user-friendly design allows for quick and effective abutment retrieval, making it a valuable addition to any dental practice focused on providing high-quality patient care.

Features

  • Precision Engineering: Designed specifically for Closefit NP abutments, ensuring a secure and accurate fit
  • Optimal Torque: Provides the necessary grip and torque for safe and effective abutment removal
  • Durable Construction: Made from high-quality materials to ensure long-lasting performance and reliability
  • User-Friendly Design: Easy to handle and operate, making it ideal for dental professionals of all experience levels
  • Efficient Extraction: Facilitates the precise and efficient removal of abutments, minimizing the risk of damage to the implant or surrounding tissues
  • Versatile Application: Suitable for various adjustment and replacement scenarios, enhancing procedural flexibility
  • Enhanced Control: Allows for precise manipulation of abutments during dental procedures, improving accuracy
  • Improved Procedural Outcomes: Contributes to the overall success of dental implant treatments by ensuring the secure management of abutments
  • Patient Safety: Designed to minimize discomfort and enhance patient care during the removal and replacement process

Description

Specification

  • Type: Retrieval Screw for Abutments
  • Length: 13.4 mm
  • Diameter: 2.0 mm
  • Functionality: Designed for the efficient retrieval of abutments from dental implants
  • Compatibility: Specifically designed for use with CloseFit NP implant systems

Packaging

  • 1 x Closefit NP retrieval screw

Direction to use

Preparation:

  • Ensure that you have the Adin Closefit NP Retrieval Screw (NP0014) and the necessary tools for the procedure
  • Verify the patient’s dental records and confirm the abutment type and position

Patient Positioning:

  • Position the patient comfortably in the dental chair, ensuring easy access to the implant site

Sterilization:

  • Sterilize the retrieval screw and any other instruments to maintain a sterile environment and prevent infections

Accessing the Abutment:

  • If applicable, remove any temporary restoration or covering material to expose the abutment

Inserting the Retrieval Screw:

  • Gently insert the retrieval screw into the internal threading of the Closefit NP abutment
  • Ensure that the screw engages properly with the abutment threads by turning it clockwise until it is securely seated

Abutment Removal:

  • Once the retrieval screw is firmly in place, use a compatible wrench or driver to apply controlled force
  • Turn the wrench or driver to unscrew and lift the abutment from the implant site
  • Be gentle to avoid damaging the surrounding tissues or the implant itself

Inspection:

  • After removal, inspect the abutment and the implant site for any signs of damage or complications
  • Clean the site if necessary, and proceed with the planned treatment or replacement

Post-Procedure Care:

  • Provide the patient with appropriate aftercare instructions to ensure proper healing and maintenance of the implant site
  • Schedule a follow-up appointment to monitor the site and ensure successful integration of any new abutment or restoration

Additional info

  • Country of Origin: Israel
  • Manufacturer: Adin

Warranty

  • Warranty is not applicable for this product.

Product Related Questions

Question : What is the primary use of the Adin Closefit NP Retrieval Screw for Abutments?
Answer:
It is designed to securely retrieve abutments from dental implants.

Question : How does the NP0014 facilitate abutment retrieval?
Answer:
The NP0014 features a precise design that ensures a secure fit with the abutments, facilitating reliable engagement and minimizing the risk of damage during retrieval.

Question : What are the dimensions of the NP0014?
Answer:
The NP0014 has a length of 13.4 mm and a diameter of 2.0 mm.

Question : Is the retrieval screw compatible with all Adin implants?
Answer:
The NP Retrieval Screw is specifically designed for use with Adin Closefit NP implants.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
View full details