adin
Adin CloseFit NP Close Tray Transfer Screw 2.8mm x 20mm (NP5127)
Adin CloseFit NP Close Tray Transfer Screw 2.8mm x 20mm (NP5127)
Couldn't load pickup availability
The Adin CloseFit NP Close Tray Transfer Screw is an essential component for achieving precise dental impressions in implant procedures. Designed for use with the closed tray technique, this screw ensures a secure connection between the impression coping and the implant, minimizing distortion during the impression-taking process. Crafted from high-quality materials, it provides durability and reliability, making it suitable for various clinical applications. Its user-friendly design allows for easy attachment and removal, streamlining the workflow for dental professionals. This transfer screw is ideal for capturing accurate implant positions, facilitating optimal outcomes in restorative dentistry.
Features
Features
- Closed Tray Design: Specifically designed for use with the closed tray impression technique, ensuring accurate transfer of implant positions
- Secure Connection: Provides a stable and secure attachment between the impression coping and the implant, minimizing distortion during impression taking
- High-Quality Material: Made from durable titanium alloy, ensuring longevity and resistance to wear during repeated use
- User-Friendly: Easy to attach and detach, streamlining the workflow for dental professionals
- Versatility: Suitable for various clinical applications, including single-tooth restorations and multiple implant cases
- Optimized for Precision: Engineered to capture detailed impressions that accurately represent the implant's position relative to surrounding tissues
- Radiographic Compatibility: Allows for radiographic verification to confirm proper seating before taking impressions
Description
Description
Specification
Specification
- Type: Close Tray Transfer Screw
- Platform: Narrow Platform (NP)
- Material: Titanium Grade 5
- Length: 20mm
- Diameter: 2.8mm
- Connection Type: Conical connection
- Compatibility: Designed for use with Adin CloseFit implants
Packaging
Packaging
- 1 x Transfer screw
Direction to use
Direction to use
Preparation
- Gather Materials: Ensure you have the transfer screw, impression coping, impression tray, and impression material ready
- Prepare the Patient: Seat the patient comfortably and explain the procedure. Ensure proper access to the implant sites
- Remove Healing Abutments: If present, carefully remove any healing caps from the implants to expose the implant fixtures
Attaching the Transfer Screw
- Select the Transfer Screw: Choose the appropriate Adin Close Tray Transfer Screw for your specific case
- Attach the Coping: Securely screw the impression coping onto each implant using the transfer screw, ensuring it is fully seated
Taking Impressions
- Prepare the Impression Tray: Apply adhesive to the impression tray to enhance retention of the impression material
- Load Impression Material: Fill the tray with heavy-body impression material, ensuring adequate coverage over the coping
- Express Light-body Material: Use light-body impression material around the coping for capturing detailed soft tissue contours
- Position the Tray: Carefully place the loaded tray into the patient's mouth, ensuring it is properly seated over all copings
- Check for Proper Seating: Verify that all copings are correctly positioned within the tray before proceeding
- Allow Material to Set: Wait for the impression material to polymerize according to manufacturer instructions
Final Steps
- Remove the Impression Tray: Once set, gently unscrew the transfer screws from each coping and carefully remove the tray from the patient's mouth.
- Inspect for Accuracy: Check that all details of the implants and surrounding tissues are captured accurately in the impression
- Attach Implant Analogs: Insert implant analogs into each coping in the impression for laboratory processing
- Send for Fabrication: Send the impression with attached analogs to your dental laboratory for prosthetic restoration fabrication
Additional info
Additional info
- Country of Origin: Israel
- Manufacturer: Adin
Warranty
Warranty
- Warranty is not applicable for this product.
Product Related Questions
Product Related Questions
Question : What is a close tray transfer screw?
Answer: A close tray transfer screw is a dental component used to secure impression copings to implants during the impression-taking process.
Question : What is the purpose of using this transfer screw?
Answer: It ensures accurate transfer of the implant position to the impression material, minimizing distortion and enhancing the precision of dental restorations.
Question : Is this transfer screw compatible with all implant systems?
Answer: No, it is specifically designed for use with Adin CloseFit implants to ensure optimal fit and function.
Question : How do I attach the transfer screw?
Answer: The transfer screw is attached by screwing it into the impression coping, which is then secured to the implant.
Share