BALDUS SEDATION
Baldus Analog -70 Oxygen-Nitrous Oxide Mixer Sedation Unit with Encased Cart
Baldus Analog -70 Oxygen-Nitrous Oxide Mixer Sedation Unit with Encased Cart
Couldn't load pickup availability
Baldus Sedation Unit (Analogue)
The Mixer Unit Baldus Analog is a versatile addition to contemporary healthcare environments, offering a seamless fit into the practice atmosphere. Its primary focus is on patient comfort, with a remarkable maximum total flow of 15 liters per minute. Safety is a central concern, evident through its integrated advisory tone that promptly alerts the operator in the event of an oxygen shortage. You do not need a power connection for analogue nitrous oxide sedation and can sedate completely independently. When developing the analog nitrous oxide device, the focus was on safety and robustness as well as handling. The device also boasts a red-marked O2 flush button on the front panel for immediate and straightforward oxygen supply, ensuring the utmost safety during sedation procedures. One notable feature is the easily readable display of nitrous oxide concentration, making it highly accessible for both dentists and the dental team. This device strikes a balance between efficiency and safety, making it an indispensable tool for dental practices. It prioritizes patient well-being and user-friendliness, creating a conducive environment for safe and comfortable sedation procedures.
- Intelligent arrangement of the valve for fresh air intake
- Max. Mixing ratio selectable between 50%, 60% or 70% N2O (standard delivery 70%)
- Automatic adjustment of the output flow (one-button operation)
- ISO color coding for EU
- Oxygen flush for immediate oxygen supply - best accessibility thanks to its "red" color on the front of the device
- Premium security package
- Check valve
- Rebreathing stop (with empty breathing bag)
- Connection for O2 demand mask
- Standard-compliant coding of the gas types
- US Patented No. 10,065,1590B2
Features
Features
- Lightweight and safe to use.
- Easy cleaning
- It can sedate completely independently.
- The Bag-T has a check valve that prevents breathing back into the bag.
- One-button control.
- Breathing bag 3 liters latex-free and autoclavable
- Connection for O2 demand mask.
- Emergency alarms in case of a lack of O2.
- 92% stainless steel and aluminum.
- No power supply is required.
- CE and FDA certified.
- Maximum total flow rate 15 l / min.
- Intelligent arrangement of the valve for fresh air intake
- Tamper-proof
Description
Description
Specification
Specification
- N2O limitation: 70%
- Maximum Total Flow: 15 l / min
- Security Package: Premium
- Dimensions: 108 x 38.5 x 29 cm
- Weight: 25 kg
- Color: Matt white
Packaging
Packaging
- 1 x Baldus analog nitrous oxide device
- 3 x Disposable adult double nose masks blueberry
- 3 x Disposable children's double nose masks strawberry
- 1 x Complete tubing set with connectors
- 1 x Baldus vacuum control block with inline flow measurement
- 1 x Breathing bag 3 liters
- 1 x Ultraslim cylinder pressure regulator O2 incl. Med. Fabric hose
- 1 x Ultraslim cylinder pressure regulator N2O incl. Med. Fabric hose
Direction to use
Direction to use
Setup and Inspection:
- Ensure the machine is placed in a suitable location in your practice.
- Inspect the equipment for any visible damage or issues before each use.
Connect Gas Sources:
- Connect the nitrous oxide and oxygen gas sources to the appropriate inlets on the machine.
Adjust Flow Rates:
- Set the desired flow rates for nitrous oxide and oxygen based on the patient's requirements. The Baldus Analog has a maximum total flow of 15 liters per minute.
Safety Check:
- Check that the integrated advisory tone system is operational. It will alert you in case of an oxygen shortage.
Start Sedation:
- Once all settings are in place, start the sedation procedure by directing the sedation gas mixture to the patient via the appropriate delivery method, such as a mask or nasal hood.
Monitoring:
- Continuously monitor the patient's condition during the sedation process, including vital signs and response to sedation.
Adjust as Needed:
- You can easily adjust the nitrous oxide concentration to maintain the desired sedation level for the patient.
Conclude Sedation:
- Once the procedure is complete, stop the sedation by discontinuing the flow of nitrous oxide and oxygen.
Disconnect Gas Sources:
- Disconnect the gas sources and turn off the machine.
Cleaning and Maintenance
Cleaning:
- Turn Off and Disconnect: Before cleaning, ensure that the nitrous oxide unit is turned off and disconnected from gas sources.
- Exterior Wiping: Use a clean, damp cloth with a mild, non-abrasive disinfectant to wipe down the exterior of the unit. Pay attention to buttons, controls, and any visible surfaces. Avoid excess moisture, especially around electrical components.
- Filters: If your unit has filters, check them regularly and replace them according to the manufacturer's recommendations.
- Tubing and Hoses: Inspect and clean the tubing and hoses. Use a mild disinfectant solution and ensure they are thoroughly dried before reconnecting.
Maintenance:
- Scheduled Maintenance: Follow the manufacturer's recommended maintenance schedule. This typically includes periodic servicing by qualified technicians.
- Gas Source Inspection: Ensure the gas sources are properly connected and in good condition. Leaks in gas lines can be hazardous and should be addressed immediately.
- Replace Components: Over time, components like seals, gaskets, and O-rings may wear out. Replace them as needed to maintain airtight connections and prevent leaks.
- Calibration: Periodically calibrate the unit to ensure accurate gas concentration delivery.
- Documentation: Keep detailed records of maintenance and servicing to ensure compliance with regulatory requirements and to track the unit's history.
- Training: Ensure that your staff is adequately trained in the operation, maintenance, and cleaning procedures.
Additional info
Additional info
- Country of Origin: Germany
Warranty
Warranty
- Manufacturer/Importer warranty of 1 Year as applicable for this product.
- Service and Warranty are handled by the manufacturer/importer directly for this product
- Dentalkart will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
- Dentalkart and the Buyer acknowledge that the Products purchased/used are a subject matter of original Manufacturer/Importer’s warranties only
- Any or all claims in relation to returns and replacement shall be made to the concerned Manufacturer/Importer only and Dentalkart may assist the customer in registering a request to get the Product replaced or serviced.
- The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be.
Please click here to know about our return policy & how warranty is covered at Dentalkart
Product Related Questions
Product Related Questions
Question: Who will be training and legal aspects ?Answer: Dentalkart team offers support for the installation of the Baldus Sedation Unit (Analogue) and provides guidance. Training for Nitrous Oxide Inhalation Sedation is recommended, and assistance can be provided for course registration upon request.
Question: What is the Baldus Analog Nitrous Acid Mixer used for?
Answer: This device is used for nitrous oxide sedation in dental and medical procedures to ensure patient comfort and relaxation.
Question:What are the advantages of using nitrous oxide sedation?
Answer: Nitrous oxide provides rapid onset and offset of sedation, minimal post-sedation recovery time, and allows patients to remain conscious and responsive during procedures.
Question: How is the oxygen supply ensured during sedation?
Answer: The unit features an integrated advisory tone for oxygen shortages and an O2 flush button for immediate oxygen supply.
Question: What is the maximum total flow of this mixer?
Answer: The Baldus Analog Nitrous Acid Mixer has a maximum total flow of 15 liters per minute.
Question: Is electricity required for its operation?Answer: No, the Baldus Analog operates independently without the need for electricity, making it versatile for various clinical settings.
Share